Toro 5010-H Lawn Mower User Manual


 
Reelmaster 5010- HPage 5 - 94Electrical System
CAUTION
Support motor/generator and bellhousing as-
semblywhen installingittop revent itfrom falling
and causing personal injury. Assembly weighs
approximately 69 pounds (31 kg).
IMPORTANT: Make sure to not damage the motor/
generator, fuellines, hydraulichoses, electricalhar-
ness, control cables or other parts while installing
the motor/generator and bellhousing assembly.
5. Lower motor/generator and bellhousing assembly
toward engine, engage motor/generator coupler hub
(item 5) into flywheel coupler flange (item 17) and slide
bellhousing to engine plate.
6. Secure bellhousing to engine plate with removed
fasteners. Make sure that r- clamps are in locations not-
ed during disassembly (Fig. 98). R- clamp that secures
motor/generator wire harness connection should cover
redtapeonharness.
7. Connect wire harness connector to motor/generator
assembly.
8. Connect hydraulic pump drive shaft to motor/gener-
ator output shaft (see Hydraulic Pump Drive Shaft in the
Service and Repairs section of Chapter 4 - Hydraulic
System). Make sure that air intake shroud fits properly
to motor/generator cover and also that air intake hose is
securedtointakeshroud.
9. Install exhaustmuffler to machine (seeExhaustSys-
tem in the Service and Repairs section of Chapter 3 -
Kubota Diesel Engine).
10.After completing installation of the motor/generator
assembly, plug the 48 VDC battery disconnect back into
the socket.
11.Lower and secure hood and operator seat.