Fault Code
Fault Description Service Suggestions
63 48 VDC pre- charge fault Disconnect one cutting reel motor at a time
until the fault is no longer a ctive to identify
faulty motor
NOTE: If cutting reel motor is faulty, additional
fault codes will likely be displayed
64 Motor/generator temperature sensor fault If this fault continues to occur, consider that
motor/generator may be faulty
65 Motorstalledon#1cuttingunit Check #1 cutting unit for excessive rotating
resistance
Check #1 cutting unit bedknife adjustment and
reel condition
Check #1 cutting unit motor for excessive ro-
tating resistance
Check that #1 cutting unit motor can rotate
without load
Replace #1 cutting unit motor if above items do
not identify problem and issue is not resolved
66 Motorstalledon#2cuttingunit Check #2 cutting unit for excessive rotating
resistance
Check #2 cutting unit bedknife adjustment and
reel condition
Check #2 cutting unit motor for excessive ro-
tating resistance
Check that #2 cutting unit motor can rotate
without load
Replace #2 cutting unit motor if above items do
not identify problem and issue is not resolved
67 Motorstalledon#3cuttingunit Check #3 cutting unit for excessive rotating
resistance
Check #3 cutting unit bedknife adjustment and
reel condition
Check #3 cutting unit motor for excessive ro-
tating resistance
Check that #3 cutting unit motor can rotate
without load
Replace #3 cutting unit motor if above items do
not identify problem and issue is not resolved