Toro 5010-H Lawn Mower User Manual


 
Reelmaster 5010- H Page 5 - 13 Electrical System
Main Menu Screen
The main menu screen can be accessed from the Info-
Center main information by pressing and releasing the
menu/back button (left button) on the display twice.
Once at the main menu screen (Fig. 18), navigation to
the five (5) different menu items can occur. Pressing the
move to menu item button (middle button) allows a dif-
ferentmenuitem tobe highlighted.Selectionofthe high-
lighted item is completed by pressing the choose menu
item button (right button).
The main menu items include faults, service, diagnos-
tics, settings and about. These menu items are de-
scribed below.
To return to the main information screen from the main
menu screen, press the back button (left button).
1. Main menu
2. Menu items
3. Move to menu items
4. Choose menu item
5. Back but ton
Figure 18
Main Menu
Faults
Service
Diagnostics
2
4
4
3
5
3
5
1
Faults Screen
The faults screen (Fig. 19) will list all machine electrical
faults that have occurred since the faults were last
cleared from the InfoCenter. The faults will be identified
by a fault number and when the fault occurred. Faults
that might occur on the machine are listed in Fault
Codes in the Troubleshooting section of this chapter.
After entry of the PIN code (see Protected Menus in the
Settings Screen of this section), the InfoCenter fault log
canbeclearedbyselectingthe clearsystemfaultsmenu
item in the faults screen. The cleared faults will be re-
moved from the InfoCenter list but will be retained in the
TEC controller memory.
If a fault occurs during machine use, there m ay be a
change in machine functionality due to the fault. Should
there be machine operation issues due to a fault, a first
step to remedy the issue would be to disengage the cut-
ting units, release the traction pedal, wait for the ma-
chinetostopmoving,turnthe ignition switch OFF and
allow all machine functions to stop. Then, attempt to re-
start the machine tosee if operation has returned tonor-
mal. Some faults will be reset during the restart and will
then allow normal function. If a fault continues to occur,
further system evaluation and possible component re-
pair or replacement will be necessary.
To return to the main menu screen from the faults
screen, press the back button (left button).
1. Fault menu
2. Fault items
3. Move to menu items
4. Choose menu item
5. Back but ton
Figure 19
Faults
Cleared @
-27.6Ago
5
#39 -13.3Ago
1
2
3
5
3
4
4
Electrical