Toro 5010-H Lawn Mower User Manual


 
Reelmaster 5010- H Page 5 - 25 Electrical System
Fault Code
Fault Description Service Suggestions
68 Motorstalledon#4cuttingunit Check #4 cutting unit for e xcessive rotating
resistance
Check #4 cutting unit bedknife adjustment and
reel condition
Check #4 cutting unit motor for excessive ro -
tating resistance
Check that #4 cutting unit motor can rotate
without load
Replace #4 cutting unit motor if above items do
not identify problem and issue is not resolved
69 Motorstalledon#5cuttingunit Check #5 cutting unit for e xcessive rotating
resistance
Check #5 cutting unit bedknife adjustment and
reel condition
Check #5 cutting unit motor for excessive ro -
tating resistance
Check that #5 cutting unit motor can rotate
without load
Replace #5 cutting unit motor if above items do
not identify problem and issue is not resolved
70 High temperature warning for #1 cutting unit Let machine cool to lower cutting unit motor
temperature
Open the r ear discharge of the cutting unit
Reduce reel speed if possible
Reduce mow speed if possible
If fault does not seem to be related to cutting
load conditions, check 48 VDC ground for #1
cutting unit motor
Consider replacement of #1 cutting unit motor
if this fault continues to occur
NOTE: A faulty sensor will not cause this fault
71 High temperature warning for #2 cutting unit Let machine cool to lower cutting unit motor
temperature
Open the r ear discharge of the cutting unit
Reduce reel speed if possible
Reduce mow speed if possible
If fault does not seem to be related to cutting
load conditions, check 48 VDC ground for #2
cutting unit motor
Consider replacement of #2 cutting unit motor
if this fault continues to occur
NOTE: A faulty sensor will not cause this fault
Electrical