Tektronix MSO4000 Landscape Lighting User Manual


 
Commands Listed in Alphabetical Order
RATE50 sets the
range of the video line scan rate to 50 kHz through 65 kHz
Examples
TRIGGER:A:VIDEO:CUSTOM:SC AN RATE15 sets the scan rate of the A trigger
custom video to Rate 1, which is 15 kHz to 2 0 kHz (standard broadcast rate).
TRIGGER:A:VIDEO:CUSTOM:SC AN? might return :TRIGGER:A:VIDEO:
CUSTOM:SCAN RATE20
indicating that the video line rate for the A trigger custom
video is set to Rate20, which is 20 kHz to 25 kHz.
TRIGger:A:VIDeo:CUSTom:SYNCInterval
Sets or queries the sync interval for the standard under test. This is only required
for BiLevel Custom. Use this command only when the video format is set to
custom.
Conditions
This command requires a DPO4VID application module.
Group
Trigger
Syntax
TRIGger:A:VIDeo:CUSTom:SY NCInterval <NR3>
TRIGger:A:VIDeo:CUSTom:SY NCInterval?
Arguments
<NR3> is the sync interval.
Examples
TRIGGER:A:VIDEO:CUSTOM:SY NCINTERVAL 4.0E-6 sets the sync interval is
set to 4.0 μs.
TRIGGER:A:VIDEO:CUSTOM:SY NCINTERVAL? might return
TRIGGER:A:VIDEO:CUSTOM:SY NCINTERVAL 4.7200E-6 indicating the sync
interval is set to 4.72 μs.
TRIGger:A:VIDeo:HDtv:FORMat
Sets or returns the HDTV video signal format on which to trigger.
Conditions
This command requires a DPO4VID application module.
Group
Trigger
2-458 MSO4000 and DPO4000 Series Programmer Manual