Commands Listed in Alphabetical Order
DATA sets the LI
N trigger condition to d ata.
IDANDDATA sets the LIN trigger condition to id and data.
WAKEup sets the LIN trigger condition to wake up.
SLEEP sets the LIN trigger condition to sleep.
ERROR sets the LIN trigger condition to error.
Examples
TRIGGER:A:BUS:B1:LIN:CONDI TION ERROR sets the LIN trigger condition
to error.
TRIGGER:A:BUS:B1:LIN:CONDI TION? might return
TRIGGER:A:BUS:B1:LIN:CONDI TION SYNCFIELD indicating the LIN trigger
condition is sync field.
TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue
Sets or returns the binary data string to be used for LIN trigger if trigger condition
is ID or IDANDDATA.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:LIN:DAT a:HIVALue <QString>
TRIGger:A:BUS:B<x>
:LIN:DATa:HIVALue?
Arguments
<QString> is a quoted string that is the binary data string used for LIN trigger if
the trigger condition is ID or IDANDDATA.
Examples
TRIGGER:A:BUS:B1:LIN:DATA: HIVALUE "11001010" sets the high value
to
11001010.
TRIGGER:A:BUS:B1:LIN:DATA: HIVALUE? might return
TRIGGER:A:BUS:B1:LIN:DATA: HIVALUE "XXXXXXXX"indicating
the high value is don’t care.
TRIGger:A:BUS:B<x>:LIN:DATa:QUALifier
Sets or returns the LIN data qualifier. This only applies if the trigger condition is
IDANDDATA or DATA.
Group
Trigger
MSO4000 and DPO4000 Series Programmer Manual 2-417