Commands Listed in Alphabetical Order
HARDCopy:PRI
NTer:LIST? (Query Only)
Returns a list o f currently attached printers.
Group
Hard Copy
Syntax
HARDCopy:PRINTer:LIST?
HARDCopy:PRINTer:RENam
e(NoQueryForm)
Renames a network p rinter on the list of available printers, replacing the currently
stored settings with the settings specified in this command. Four arguments must
be present, but the argum
ents may be empty strings if the value for a field is
to be deleted.
Group
Hard Copy
Syntax
HARDCopy:PRINTer:REName
<name>,<new_name>,<new_ser ver>,<new_addre ss>
Arguments
<name> is the name of the printer to be deleted.
<new_name> is the new name for this printer.
<new_server> is the new print server for this printer.
<new_address> is the new IP ad
dress for the server.
HEADer
Sets or returns the Response Header Enable State that causes the oscilloscope to
either include or omit headers on query responses.
NOTE. This command does not affect IEEE Std 4 88.2-1987 Common Commands
(those starting with an asterisk); these commands never return headers. This
command does affect the R
esponse Header Enable State of both the USBTMC and
VXI-11 interfaces. Refer to the Introduction for additional information.
Group
Miscellaneous
MSO4000 and DPO4000 Series Programmer Manual 2-185