Commands Listed in Alphabetical Order
Group
Vertical
Syntax
REF<x>:VERTical:POSition <NR3>
REF<x>:VERTical:POSition?
Related Commands
CH<x>:POSition, MATH[1]:VERTical:POSition
Arguments
<NR3> is the desired position, in divisions from the center horizontal graticule.
The range is from -5.0 to 5.0 divisions.
Examples
REF2:VERTICAL:POSITION 1.3E+00 positions the Reference 2 input signal
1.3 divisions above the center horizontal g raticule.
REF1:VERTICAL:POSITION? might return :REF1:VERTICAL:POSITION
-1.3000E+00
indicating that the current position of Reference 1 is 1.3 divisions
below the center horizontal graticule.
REF<x>:VERTical:SCAle
Sets or returns the vertical scale for the reference waveform specified by <x>,
where x is the reference channel number.
Each waveform has a vertical scale parameter. For a signal with constant
amplitude, increasing the Scale causes the waveform to be displayed smaller.
Decreasing the scale causes the waveform to be displayed larger.
Scale affects all waveforms, but affects reference and math waveforms differently
from channel waveforms:
For reference and math waveforms, this setting controls the display only,
graphically scaling these waveforms and having no affect on the acquisition
hardware.
For channel waveforms, this setting controls the vertical size of the a cquisition
window as well as the display scale. The range and resolution of scale
values depends on the probe attached and any other external factors you have
specified.
Group
Vertical
Syntax
REF<x>:VERTical:SCAle <NR3>
REF<x>:VERTical:SCAle?
Related Commands
CH<x>:SCAle, MATH[1]:VERTical:SCAle
MSO4000 and DPO4000 Series Programmer Manual 2-321