Commands Listed in Alphabetical Order
TRIGger:A:BU
S:B<x>:SPI:DATa{:OUT|:MOSI}:VALue
Sets or returns the binary data string to be used for a SPI trigger if the trigger
condition is MOSI or MISOMOSI. Applies to bus <x>, where x is the bus number.
Conditions
This command requires a DPO4EMBD application module.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:SPI:DA Ta{:OUT|:MOSI}:V ALue <QStrin g>
TRIGger:A:BUS:B<x>:SPI:DA Ta{:OUT|:MOSI}:V ALue?
Arguments
<QString> is the binary data string with the number of bits specified by the
TRIGger:A:BUS:B<x>:SPI:DATa:SIZe command. The only allowed characters
in the
QString are0,1,andX.
TRIGger:A:BUS:B<x>:SPI:DATa:SIZe
Sets or returns the length of the data string to be used for a SPI trigger if the
trigger condition is MISO, MOSI, or MISOMOSI. Applies to bus <x>, where x
is the bus number.
Conditions
This command requires a DPO4EMBD application module.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:SPI:DA Ta:SIZe <NR1>
TRIGger:A:BUS:B<x>:SPI:DA Ta:SIZe?
Arguments
<NR1> is the length of the data string in bytes.
TRIGger:A:BUS:SOUrce
Sets or returns the source for a Serial bus trigger.
Conditions
This command requires a DPO4AUTO or DPO4EMBD application m odule.
Group
Trigger
2-424 MSO4000 and DPO4000 Series Programmer Manual