Reelmaster 7000Hydraulic System Page 4 -- 66
Gear Pump P4 Flow (Cooling Fan Circuit) Test (Using Tester with Pressure Gauges and
Flow Meter)
Working Pressure
Low Pressure
Return or Suction
Flow
.071
VALVE
PSI
BYPASS
P1
.091
5000
.56.56
P4
1.031.03
P2P3
PSI
5000
.071
PISTONPUMP
GEAR
PUMP
2.48
ENGINESPEED
2850/1550
TOFANCIRCUIT
TOSTEERINGAND LIFTCIRCUITS
FROMRESERVOIR FROMFILTRATIONMANIFOLD
TESTER
TOMOW CONTROL
MANIFOLD (P1PORT)
TOMOW CONTROL
MANIFOLD (P2PORT)