Commands Listed in Alphabetical Order
Conditions
This command re
quires DPO4AUDIO a pplication module.
Group
Bus
Syntax
BUS:B<1-4>:AUDio:CLOCk:POL arity {FALL|RI
Se}
BUS:B<1-4>:AUDio:CLOCk:POL arity?
Arguments
FALL sets falling edge as the clock polarity.
RISe sets rising edge as the clock polarity.
Examples
BUS:B1:AUDIO:CLOCK:POLARIT Y Fall sets the clock polarity to Fall.
BUS:B1:AUDIO:CLOCK:POLARIT Y? might return
:BUS:B1:AUDIO:CLOCK:POLARI TY RISe indicating that the clock polarity
is set to Rise.
BUS:B<1-4>:AUDio:CLOCk:SOUrce
Sets or returns the clock source waveform for the AUDIO bus.
Conditions
This command requires DPO4AUDIO application module.
Group
Bus
Syntax
BUS:B<1-4>:AUDio:CLOCk:SOU rce {CH1|CH2|CH3|CH4|
D0|D1|D2|D3|D4|D5|D6|D7|D8 |D9|D10|D11|D12 |D13|D14|D15}
BUS:B<1-4>:AUDio:CLOCk:SOU r
ce?
Arguments
CH1–Ch4 or D0–D15 species the clock source for the audio bus.
Examples
BUS:B1:AUDIO:CLOCK:SOURCE D1 sets D1 as the clock source for the audio
bus.
BUS:B1:AUDIO:CLOCK:SOURCE? might return
:BUS:B1:AUDIO:CLOCK:SOURCE CH1 indicating that the clock source is
set to CH1.