Commands Listed in Alphabetical Order
Examples
AUXIN:PROBE? m
ight return
AUXIN:PROBE:ID:TYPE "No Probe
Detected";SERNUMBER "";:AUXIN:PROBE:UNITS "";RE SISTANCE
1.0000E+6
giving information about the probe attached to the AUX In input.
AUXin:PRObe:AUTOZero (No Query Form)
Sets the TekVPI probe attached to the Aux In input to autozero. The oscilloscope
will ignore this command if the Auxiliary input does not have a TekVPI probe
connected to it.
Group
Vertical
Syntax
AUXin:PRObe:AUTOZero {EXECute}
Arguments
EXECute sets the probe to autozero.
Examples
AUXin:PROBE:AUTOZERO EXECUTE
AUXin:PRObe:COMMAND (No Query Form)
Sets the state of the probe control sp
ecified with the first argument to the state
specified with the second argument. The commands and states are unique to the
attached probe type. Only certain VPI probes support this command. See the
probe documentation for how to set these string arguments.
Group
Vertical
Syntax
AUXin:PRObe:COMMAND <QString>, < QString>
Arguments
<QString> are quoted strings specifying the probe command and value to set in
the probe attached to the auxiliary input.
Examples
AUXIN:PROBE:COMMAND “OUTPUT”, “ON” turns the output of a Tektronix
VPI-DPG probe on.
AUXIN:PROBE:COMMAND “MODE”, “4–4V1MHz” sets a Tektronix VPI-DPG
probe to t
he 4-4V1MHz mode.
AUXIN:PROBE:COMMAND?“MODE” might return AUXIN:PROBE:COMMAND
“MODE”,“4-4V1MHZ”
.
MSO4000 and DPO4000 Series Programmer Manual 2-79