Commands Listed in Alphabetical Order
TRIGger:A:BU
S:B<x>:FLEXray:FRAMEType
Sets or returns the frame type for FLEXRAY.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:FLEXra y:FRAMEType
{NORMal|PAYLoad|NULL|SYNC |STARTup}
TRIGger:A:BUS:B<x>:FLEXra y:FRAMEType?
Arguments
NORMal species the normal frame type.
PAYLoad species the p ayload frame type.
NULL species the null frame type.
SYNC species the sync frame type.
STARTup species the startup frame type.
Examples
TRIGGER:A:BUS:B1:FLEXRAY: FRAMETYPE PAYLOAD sets the frame type to
payload.
TRIGGER:A:BUS:B1:FLEXRAY: FRAMETYPE? might return
TRIGGER:A:BUS:B1:FLEXRAY: FRAMETYPE NORMAL indicating the
frametypeissettonormal.
TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC
Sets or returns th
e CRC portion of the binary header string to be used for
FLEXRAY trigger.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:FLEXra y:HEADER:CRC <QString>
TRIGger:A:BUS:B<x>:FLEXra y:HEADER:CRC?
Arguments
<QString> is a quoted string that is the C RC portion of the binary header string.
Examples
TRIGGER:A:BUS:B1:FLEXRAY: HEADER:CRC “11001100101” sets the CRC
portion of the binary header string to 11001100101.