Tektronix DPO4000 Landscape Lighting User Manual


 
Commands Listed in Alphabetical Order
Group
Cursor
Syntax
CURSor:HBArs:DELTa?
Related Commands
CURSor:HBArs:UNIts
Returns
A oating point value with an exponent.
Examples
CURSOR:HBARS:DELTA? might return :CURSOR :HBARS:DELTA 5.0800E+00
indicating that the difference between the two cursors is 5.08.
CURSor:HBArs:POSITION<x>
Sets or returns the horizontal bar cursor position relative to ground, which is
expressed in vertical units (usually volts). The cursor is specied by x, which
can be 1 or 2.
Group
Cursor
Syntax
CURSor:HBArs:POSITION<x> <NR3>
CURSor:HBArs:POSITION<x>?
Related Commands
CURSor:FUNCtion
Arguments
<NR3> species the c ursor position relative to ground.
Examples
CURSOR:HBARS:POSITION1 25.0E-3 positions Cursor 1 of the horizontal
cursors at 25 mV.
CURSOR:HBARS:POSITION2? might return :CURSOR:H BARS:POSITION2
-64.0000E-03
indicating that Cursor 2 of the horizontal bar cursors is at -64 mV.
CURSor:HBArs:UNIts
Sets or returns the units for the horizontal bar cursors.
Group
Cursor
2-134 MSO4000 and DPO4000 Series Programmer Manual