Tektronix DPO4000 Landscape Lighting User Manual


 
Commands Listed in Alphabetical Order
Syntax
POWer:SWLoss:
CONDuction:ENERGY:MAX?
Examples
POWER:SWLOSS:CONDUCTION:EN ERGY:MAX? might return
:POWER:SWLOSS:CONDUCTION:E NERGY:MAX 1 indicating that the
maximum conduction energy switching loss calculation is set to 1 J.
POWer:SWLoss:CONDuction:ENERGY:MEAN? (Query Only)
Returns the mean conduction energy in the conduction period for the switching
loss calculation.
Conditions
This command requires a DPO4PWR application m odule.
Group
Power
Syntax
POWer:SWLoss:CONDuction:EN ERGY:MEAN?
Examples
POWER:SWLOSS:CONDUCTION:EN ERGY:MEAN? might return
:POWER:SWLOSS:CONDUCTION:E NERGY:MEAN 1 indicating that the me
an
conduction energy switching loss calculation is set to 1 J.
POWer:SWLoss:CONDuction:ENERGY:MIN? (Query Only)
Returns the minimum conduction energy for the switching loss calculation.
Conditions
This command requires a DPO4PWR application m odule.
Group
Power
Syntax
POWer:SWLoss:CONDuction:EN ERGY:MIN?
Examples
POWER:SWLOSS:CONDUCTION:EN ERGY:MIN? might return
:POWER:SWLOSS:CONDUCTION:E NERGY:MIN 1 indicating that the
minimum conduction energy switching loss calculation is set to 1 J.
MSO4000 and DPO4000 Series Programmer Manual 2-299