Tektronix DPO4000 Landscape Lighting User Manual


 
Commands Listed in Alphabetical Order
Conditions
This command re
quires a DPO4EMBD application module.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:I2C:DA Ta:SIZe <NR1>
TRIGger:A:BUS:B<x>:I2C:DA Ta:SIZe?
Arguments
<NR1> is the length of the data string in bytes.
TRIGger:A:BUS:B<x>:I2C:DATa:VALue
Sets or returns the binary data string used for I2C triggering if the trigger condition
is DATA or ADDRANDDATA. Applies to bus <x>, where x is the bus number.
Conditions
This command requires a DPO4EMBD application module.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:I2C:DA Ta:VALue <QString>
TRIGger:A:BUS:B<x>:I2C:DA Ta:VALue?
Arguments
<QString> is the binary d ata string, where the number of bits is 8 times the
number of bytes specied. The only allowed characters in the string are 0, 1,
and X.
TRIGger:A:BUS:B<x>:LIN:CONDition
Sets or returns the trigger condition for LIN.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:LIN:CO NDition
{SYNCField|IDentifier|DAT A|IDANDDATA|WAKE up|SLEEP|ERROR}
TRIGger:A:BUS:B<x>:LIN:CO NDition?
Arguments
SYNCField sets the LIN trigger condition to sync eld.
IDentifier sets the LIN trigger condition to identier.
2-416 MSO4000 and DPO4000 Series Programmer Manual