Tektronix DPO4000 Landscape Lighting User Manual


 
Commands Listed in Alphabetical Order
Syntax
TRIGger:A:BUS
:B<x>:FLEXray:CYCLEcount:VAL ue <QString>
TRIGger:A:BUS:B<x>:FLEXra y:CYCLEcount:VAL ue?
Arguments
<QString> is a quoted string that is the FLEXRAY binary data string that is the
cycle count low value.
Examples
TRIGGER:A:BUS:B1:FLEXRAY: CYCLECOUNT:VALUE “11001101” sets the
cycle count value to 11001101.
TRIGGER:A:BUS:B1:FLEXRAY: CYCLECOUNT:VALUE ? might return
TRIGGER:A:BUS:B1:FLEXRAY: CYCLECOUNT:VALUE "XXXXXX" indicating the
cycle count value is don’t care.
TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue
Sets or returns the high binary data string to be used for FLEXRAY trigger if
trigger condition is ID or IDANDDATA.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:FLEXra y:DATa:HIVALue <QString>
TRIGger:A:BUS:B<x>:FLEXra y:DATa:HIVALue?
Arguments
<QString> is a quoted string that is the FLEXRAY binary data high value.
Examples
TRIGGER:A:BUS:B1:FLEXRAY: DATA:HIVALUE
"11001101XXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXX
XXXXXXX1"
sets the binary data string high value to
"11001101XXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXX
XXXXXXX1"
.
TRIGGER:A:BUS:B1:FLEXRAY: DATA:HIVALUE? might
return
TRIGGER:A:BUS:B1:FLEXRAY:DA TA:HIVALUE
"XXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXX
XXXXXXXX"
indicating the binary data string high value is don’t care.
TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet
Sets or returns the offset of the data string in bytes to be used for FLEXRAY
trigger.
2-404 MSO4000 and DPO4000 Series Programmer Manual