Tektronix DPO4000 Landscape Lighting User Manual


 
Commands Listed in Alphabetical Order
Examples
TRIGGER:A:BUS
:B1:CAN:CONDITION?
might return :TRIGGER:A:BUS:B1:
CAN:CONDITION EOF indicating an end of le condition.
TRIGGER:A:BU
S:B1:CAN:CONDITION DATA
enables triggering on matching
CAN data.
TRIGger:A:BUS:B<x>:CAN:DATa:DIRection
Sets or returns the CAN trigger data direction to be v alid on a Read, Write,
or Either condition for bus <x>, where x is the bus number. This applies only,
if the trigger condition is ID.
Conditions
Requires a DPO4AUTO application module.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:CAN:DA Ta:DIRection {READ|WRITE|NOC ARE}
TRIGger:A:BUS:B<x>:CAN:DA Ta:DIRection?
Arguments
READ sets the CAN data direction to READ.
WRITE sets the CAN data direction to WRITE.
NOCARE sets the CAN data direction to e ither.
Examples
TRIGGER:A:BUS:B1:CAN:DATA :DIRECTION WRITE sets the CAN data
direction to Write.
TRIGger:A:BUS:B<x>:CAN:DATa:QUALier
Sets or returns the CAN data qualier for bus <x>, where x is the bus number.
This applies only, if the trigger condition is IDANDDATA o r DATA.
Conditions
Requires a DPO4AUTO application module.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:CAN:DA Ta:QUALifier
{LESSThan|Than|EQUal|UNEQ ual|LESSEQual|EQ ual}
TRIGger:A:BUS:B<x>:CAN:DA Ta:QUALifier?
2-398 MSO4000 and DPO4000 Series Programmer Manual