Commands Listed in Alphabetical Order
MATH specifies t
he math waveform as the waveform that is affected by the
front-panel controls.
BUS<x> specifi
es a bus waveform as the waveform affected by the front-panel
controls. <x> specifies the bus number.
Returns
NONE if all t
he channels are turned off.
NONE is ignored on input.
Examples
SELECT:CONTROL CH2 resets acquisition displays on c hannel 2, and causes the
selected
waveform to be the implied object of waveform commands.
SELECT:CONTROL? might return :SELECT:CONTROL MATH indicating that math
is the im
plied object of waveform commands.
SELect:D<x>
Turns on the display of the digital channel <x> and resets the acquisition. <x > is
the channel number. The query returns whether the channel is on or off but does
not indicate whether it is the selected waveform.
Grou
p
Vertical
Syntax
SELect:D<x> {<NR1>|OFF|ON}
SELect:D<x>?
Arguments
ON turns on the display of the specified waveform. This waveform also bec omes
the s elected waveform.
OFF turns off the display of the specified waveform.
<NR1> = 0 turns off the display of the specified waveform; any other value turns
on the display of the specified waveform.
Examples
SELECT:D2 ON turns the digital channel 2 waveform display on, and selects
digital channel 2.
SELECT:D2? might return :SELECT:D2 1 indicating that digital channel 2 is
being displayed.
MSO4000 and DPO4000 Series Programmer Manual 2-385