Tektronix DPO4000 Landscape Lighting User Manual


 
Commands Listed in Alphabetical Order
PICTBridge:P
RINTQual
Sets or returns the output print quality.
Group
PictBridge
Syntax
PICTBridge:PRINTQual {DEFLT|NRMAL|FINE|DRAFT}
Arguments
DEFLT for the default quality print.
NRMAL for a normal quality print.
FINE for a ne quality print.
DRAFT for a draft quality print.
Examples
PICTBRIDGE:PRINTQUAL FINE sets the print quality to Fine.
PICTBRIDGE:PRINTQUAL? might return PICTBRIDGE :PRINTQUAL DEFLT
indicating the default quality print.
POWer:CURRENTSOurce
Sets or returns the current source for the power application.
Conditions
This command requires a DPO4PWR application m odule.
Group
Power
Syntax
POWer:CURRENTSOurce {CH1|CH2|CH3|CH4|REF1|REF2|REF3|REF4}
POWer:CURRENTSOurce?
Arguments
CH1–CH4 sets an analog channel as the current source.
REF1–REF4 sets a reference as the current source.
Examples
POWER:CURRENTSOURCE CH1 sets the current source as CH1.
POWER:CURRENTSOURCE? might return POWER:CU RRENTSOURCE CH2 indicating
that CH2 is the current source.
MSO4000 and DPO4000 Series Programmer Manual 2-247