Commands Listed in Alphabetical Order
Group
Status and Erro
r
Syntax
*STB?
Related Commands
*CLS, DESE, *ESE, *ESR?, EVENT?, EVMsg?, FACtory, *SRE
Returns
<NR1>
Examples
*STB? might return 96, showing that the SBR contains the binary value 01100000.
TEKSecure (No Query Form)
This command initializes both waveform and setup memories, overwriting any
previously stored data. These are the WFMInpre?, WFMOutpre?,andDATa
command values after the
TEKSecure operation.
:WFMOUTPRE:BYT_NR 1 :WFMOUTPRE:BIT _NR 8 :WF MOUTPRE:ENCDG
BIN :WFMO UTPRE:BN_FMT RI :WFMOUTPRE:BYT_OR MSB
:WFMOUTPRE:WFID "Ch1, DC coupling, 100.0mV/div,
4.000us/div, 10000 po ints, Sample mode" :WFMOUTPRE:NR_P T
10000 :WF MOUTPRE:PT_FMT Y :WFMOUTPRE:XUNIT "s"
:WFMOUTPRE:XINCR 4.0000E-9 :WFMOUTPRE :XZERO -20.0 000E-6
:WFMOUTPRE:PT_OFF 0 :WFMOUTPRE:YUN IT "V" :W FMOUTPRE:YMULT
4.0000E-3 :WFMOUTPRE:YOFF 0.0000 : WFMOUTPRE:YZERO 0.0000
:WFMINPRE:BYT_NR 1 :W FMINPRE:BIT_NR 8 :WFMINPRE:ENCDG
BIN :WFMI NPRE:BN_FMT RI :WFMINPRE:BYT_OR MS B
:WFMINPRE:NR_PT 10000 :WFMINPRE:PT_FM T Y :WFMI NPRE:XUNIT
"s" :WFMI NPRE:XINCR 4.0000E-9 :WFMINPRE:XZERO 0.0000
:WFMINPRE:PT_OFF 0 :W FMINPRE:YUNIT "V" :WFMINPRE:YMULT
4.0000E-3 :WFMINPRE:YOFF 0.0000 :W FMINPRE:YZERO 0.0000
DATA:DESTINATION REF1 DATA:ENCDG R IBINARY DATA:SOURCE C H1
DATA:START 1 DATA:STO P 10000 D ATA:WIDTH 1
NOTE. The TEKSecure command can take up to five minutes to complete. The
oscilloscope is inoperable during this period.
Group
Miscellaneous
Syntax
TEKSecure
2-390 MSO4000 and DPO4000 Series Programmer Manual