Tektronix DPO4000 Landscape Lighting User Manual


 
Commands Listed in Alphabetical Order
Syntax
SEARCH:SEARCH
<x>:TRIGger:A:SETHold:THResh old:CH<x> <NR3>
SEARCH:SEARCH<x>:TRIGger:A :SETHold:THResh old:CH<x>?
Arguments
<NR3> is the lower threshold in volts.
SEARCH:SEARCH<x>:TRIGger:A:SETHold:THReshold{:MATH|:MATH1}
Sets or returns the trigger search setup and hold threshold for the math waveform.
This helps to determine where to place search marks. Search<x> is the search
number, which is always 1.
Conditions
MSO oscilloscopes only.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A :SETHold:THResh old{:MATH|:MATH1}
<NR3>
SEARCH:SEARCH<x>:TRIGger:A :SETHold:THResh old{:MATH|:MATH1}?
Arguments
<NR3> is the lower threshold in volts.
SEARCH:SEARCH<x>:TRIGger:A:SETHold:THReshold:REF<x>
Sets or returns the trigger search setup and hold threshold for the selected reference
waveform. This helps to determine where to place search marks. Search<x> is the
search numbe r, which is always 1. REF<x> is the referenc e waveform numbe r.
Conditions
MSO oscilloscopes only.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A :SETHold:THResh old:REF<x> <N R3>
SEARCH:SEARCH<x>:TRIGger:A :SETHold:THResh old:REF<x>?
Arguments
<NR3> is the lower threshold in volts.
MSO4000 and DPO4000 Series Programmer Manual 2-379