Commands Listed in Alphabetical Order
Examples
MATHVAR:VAR2 -
2.43E-5
stores the value -2.43e-5 in the second m ath variable
location.
MATHVAR:VAR2
?
might return :MATHVAR:VAR2 24.3000E-6 for the
expression stored in location 2.
MEASUrement? (Query Only)
Returns all measurement parameters.
Group
Measurement
Syntax
MEASUrement?
Examples
MEASUREMENT? might return :MEASUREMENT:IMMED:DELAY:DIRECTION
FORWARDS;EDGE1 RISE;EDGE2 RISE;: MEASUREMENT:IMMED:TYPE
PERIOD;UNITS "s";SOURCE1 CH1;SOURCE 2
CH2;:MEASUREMENT:MEAS1:DEL AY:DIRECTION FORWARDS;EDGE1
RISE;EDGE2 RISE;:MEASUREMENT:MEAS1:STA TE 1;TYP
E
FREQUENCY;UNITS "Hz";SOURCE1 CH1 ;SOURCE2 CH2 ;COUNT
0;MAXIMUM 0.0000;MEAN 0.0000;MINIMU M 0.0 000 ;STDDEV
0.0000;:MEASUREMENT:MEAS2: DELAY:DIRECTION FORWARDS;EDG E1
RISE;EDGE2 RISE;:MEASUREMENT:MEAS2:STA TE 1;TYPE PERIOD;UNITS
"s";SOURCE1 CH1;SOURCE2 CH2;COUNT 0;MAXIMUM 0.0000;MEAN
0.0000;MINIMUM 0.0000;STDDEV 0.0 000;:MEASUR
EMENT:MEAS3:
DELAY:DIRECTION FORWARDS;EDGE1 R ISE;EDGE2
RISE;:MEASUREMENT:MEAS3:ST ATE 1;TYPE PK2PK;UNITS "V";SOURCE1
CH1;SOURCE2 CH2;COUNT 0;MAXIMUM 0.0000;MEAN 0.0000;MINIMUM
0.0000;STDDEV 0.0000;:MEASUREMENT:MEAS 4:DELAY:DIRECTIO N
FORWARDS;EDGE1 RISE;EDGE2 RISE;: MEASUREMENT:MEAS4:STATE
0;TYPE PERIOD;UNITS "s";SOURCE1 CH1;SOURC
E2 CH2;CO UNT
0;MAXIMUM 0.0000;MEAN 0.0000;MINIMU M 0.0000;STDDEV
0.0000;:MEASUREMENT:METHOD AUTO;REFLEV EL:METHOD
PERCENT;ABSOLUTE:HIGH 0.0000;LOW 0.0000;MID1
0.0000;MID2 0.0000;:MEASUREMENT:REFLEV EL:PERCENT:HIGH
90.0000;LOW 10.0000;MID1 50.0000;MI D2
50.0000;:MEASUREMENT:INDIC ATORS:STA
TE
OFF;NUMHORZ 0;NUMVERT 0;HORZ1 9 9.0000E +36;HORZ2
99.0000E+36;HORZ3 99.0000E+36;HORZ4 99.0000E+36;VERT1
99.0000E+36;VERT2 99.0000E+36;VERT3 99.0000E+36;VERT4
99.0000E+36;:MEASUREMENT:S TATISTICS:MODE OFF;WEIGHTING
32;:MEASUREMENT:GATING SCREEN
.
MSO4000 and DPO4000 Series Programmer Manual 2-205