Tektronix 071-0855-05 Telescope User Manual


 
Reference: Remote Commands ~ Command Description
OTS9100 User Manual 3-61
:SOURce:INSErt:DEFEct:TIME:RANGe
This query returns a units keyword and two integer numbers representing the minimum and maximum
duration values for timed defects. The units keyword is one of FRAME, US, MS, S, SEC10 (0.1S), and
SEC100 (0.01S).
Syntax :SOURce<slot>:INSErt:DEFEct:TIME:RANGe? <Enum>
Parameter Description
NONE No defect is selected
LOS Loss of signal
LOF Loss of frame
AIS_L Line AIS
RDI_L Line RDI
AIS_P Path AIS
RDI_P Path RDI
RDIPAY_P Path RDI (Payload)
RDISRV_P Path RDI (Server)
RDICON_P Path RDI (Connectivity)
LOP_P Path loss of pointer
:SOURce:INSErt:DEFEct:TYPE
This command selects the type of defect inserted. The query form returns the current selection.
Syntax :SOURce<slot>:INSErt:DEFEct:TYPE?
:SOURce<slot>:INSErt:DEFEct:TYPE <Enum>
Parameters Description
NONE No defect is selected
LOS Loss of signal
LOF Loss of frame
AIS_L Line AIS
RDI_L Line RDI
AIS_P Path AIS
RDI_P Pat RDI
RDIPAY_P Path RDI (Payload)
RDISRV_P Path RDI (Server)
RDICON_P Path RDI (Connectivity)
LOP_P Path loss of pointer
:SOURce:INSert:IP:ANOMaly:MODE
This command specifies how IP anomalies are inserted. The query form returns the current setting.
Syntax :SOURce<slot>:INSert:IP:ANOMaly:MODE?
:SOURce<slot>:INSert:IP:ANOMaly:MODE <Parameter>
Parameters Description
NONE IP anomaly insertion is disabled
SINGle A single IP anomaly is inserted
CONTinuous IP anomalies are inserted continuously, at the programmed rate