Reference: Remote Commands ~ Command Description
OTS9100 User Manual 3-23
:SENSe:ANALysis:GR253A:SECTion
This query returns the value of the specified Section parameter from GR-253 analysis of received data.
Syntax :SENSe<slot>:ANALysis:GR253A:SECTion? <Enum>
Parameters Description
CV_C CV Count
CV_R CV Count ratio
BBE_C Background block errors
BBE_R Background block error ratio
ES_C Errored seconds
ES_R Errored second ratio
SES_C Severely errored seconds
SES_R Severely errored second ratio
ESA_C Errored seconds type A
ESA_R Errored second type A ratio
ESB_C Errored seconds type B
ESB_R Errored second type B ratio
CSES_C Consecutive SES periods
UAS_C Unavailable seconds
UAS_R Unavailable seconds error ratio
SEFS_C Severely errored framing seconds
SEFS_R Severely errored framing second ratio
:SENSe:ANALysis:GR253A:SECTion:ALL
This query returns the values of all of the Section parameters from GR-253 analysis of received data. The
parameters are returned in the order in which they are listed under :SENSe:ANALysis:GR253A:SECTion.
Syntax :SENSe<slot>:ANALysis:GR253A:SECTion:ALL?
:SENSe:ANALysis:PATH:HPPLM
This command enables or disables the inclusion of Path Label Mismatch errors in the analysis of received
signals. The query form returns the current setting.
Syntax: :SENSe<slot>:ANALysis:PATH:HPPLM?
:SENSe<slot>:ANALysis:PATH:HPPLM <Boolean>