Tektronix 071-0855-05 Telescope User Manual


 
Reference: Remote Commands ~ Command Description
OTS9100 User Manual 3-51
:SOURce:DATA:PATH:OVERhead:PASSthru:ALL
This command controls the source of transmitted path overhead data in Through Mode. The parameter is
a numeric value in which each bit enables retransmission of received data for one specific path overhead
field. The bit values are shown under :SOURce:DATA:PATH:OVERhead:PASSthru. The query form
returns the current setting.
Syntax :SOURce<slot>:DATA:PATH:OVERhead:PASSthru:ALL?
:SOURce<slot>:DATA:PATH:OVERhead:PASSthru:ALL <NR1>
:SOURce:DATA:PATH:TRACe
This command sets the data sequence length and data byte values transmitted in the Path Trace (J1)
byte of the Path Overhead. The data bytes are formatted as a standard IEEE-488 data block. The query
form returns the current settings.
Syntax: :SOURce<slot>:DATA:PATH:TRACe?
:SOURce<slot>:DATA:PATH:TRACe <Enum> ,<Block>
Parameters Description
L1B Constant 8-bit data
L16B A repeating sequence of 16 bytes, 0-filled with CRC
L16FREE A repeating sequence of 16 bytes, arbitrary format
L64B A repeating sequence of 64 bytes, space-filled with CR/LF
L64FREE A repeating sequence of 64 bytes, arbitrary format
:SOURce:DATA:PATH:TRACe:TYPE
This command sets the data sequence length transmitted in the Path (J1) byte of the Path Overhead. The
query form returns the current setting.
Syntax: :SOURce<slot>:DATA:PATH:TRACe:TYPE?
:SOURce<slot>:DATA:PATH:TRACe:TYPE <Enum>
Parameters Description
L1B Constant 8-bit data
L16B A repeating sequence of 16 bytes, 0-filled with CRC
L16FREE A repeating sequence of 16 bytes, arbitrary format
L64B A repeating sequence of 64 bytes, space-filled with CR/LF
L64FREE A repeating sequence of 64 bytes, arbitrary format