Tektronix 071-0855-05 Telescope User Manual


 
Reference: Remote Commands ~ Command Description
3-28 OTS9100 User Manual
:SENSe:DATA:CHANnel
This command selects the active channel for the received signal. The query form returns the current
setting.
Syntax: :SENSe<slot>:DATA:CHANnel?
:SENSe<slot>:DATA:CHANnel <NR1>
:SENSe:DATA:IP:PAYLoad:PATTern
This command selects the test pattern inserted as IP payload into the received signal. The query form
returns the current setting.
Syntax :SENSe<slot>:DATA:IP:PAYLoad:PATTern?
:SENSe<slot>:DATA:IP:PAYLoad:PATTern <Parameter>
Parameters Description
PRBS31A ITU standard PRBS 2^31-1 pattern
PRBS31I Inverted PRBS 2^31-1 pattern
USER Constant 16-bit user-specified data
:SENSe:DATA:IP:PAYLoad:PATTern:UDATA
This command specifies the data value inserted into the received signal when constant data is selected
for the IP test pattern. The query form returns the current setting.
Syntax :SENSe<slot>:DATA:IP:PAYLoad:PATTern:UDATA?
:SENSe<slot>:DATA:IP:PAYLoad:PATTern:UDATA <NR1>
:SENSe:DATA:IP:STReam:INDEX
This query form returns the current setting.
Syntax :SENSe<slot>:DATA:IP:STReam:INDEX?
:SENSe:DATA:PATH:TRACe
This query returns the most recently received J1 path trace type (length) and data. See the command
:SOURce:DATA:PATH:TRACe for the formats of the enum and block values returned. The data bytes are
returned in standard IEEE-488 block data format.
Syntax: :SENSe<slot>:DATA:PATH:TRACe?