Reference: Remote Commands ~ Command Description
3-22 OTS9100 User Manual
:SENSe:ANALysis:GR253A:PATH:NEAR
This query returns the value of the specified Near-End Path parameter from GR-253 analysis of received
data. Ratios are returned as NR3 values, other parameters as NR1 values.
Syntax: :SENSe<slot>:ANALysis:GR253A:PATH:NEAR? <Enum>
Parameters Description
CV_C CV Count
CV_R CV Count ratio
BBE_C Background block errors
BBE_R Background block error ratio
ES_C Errored seconds
ES_R Errored second ratio
SES_C Severely errored seconds
SES_R Severely errored second ratio
ESA_C Errored seconds type A
ESA_R Errored second type A ratio
ESB_C Errored seconds type B
ESB_R Errored second type B ratio
CSES_C Consecutive SES periods
UAS_C Unavailable seconds
UAS_R Unavailable seconds error ratio
:SENSe:ANALysis:GR253A:PATH:NEAR:ALL
This query returns the values of all of the Near-End Path parameters from GR-253 analysis of received
data. Ratios are returned as NR3 values, other parameters as NR1 values. The parameters are returned
in the order in which they are listed under :SENSe:ANALysis:GR253A:PATH:NEAR.
Syntax: :SENSe<slot>:ANALysis:GR253A:PATH:NEAR:ALL?