Tektronix 071-0855-05 Telescope User Manual


 
Reference: Remote Commands ~ Command Description
OTS9100 User Manual 3-31
:SENSe:DATA:RATE
This query returns the input signal rate expected by the OTS-9000 receiver.
Syntax :SENSe<slot>:DATA:RATE?
Parameters Description
G10A 10 Gb/s (OC-192 or STM-64)
:SENSe:DATA:SECTion:TRACe
This query returns the most recently received J0 section trace type (length) and data. The data bytes are
returned in standard IEEE-488 block data format.
Syntax :SENSe<slot>:DATA:SECTion:TRACe?
:SENSe:DATA:SECTion:TRACe:TYPE
This query returns the most recently received J0 section trace type (length).
Syntax :SENSe<slot>:DATA:SECTion:TRACe:TYPE?
:SENSe:DATA:SECTion:TRACe:VALUe
This query returns the most recently received J0 section trace data. The data bytes are returned in IEEE-
488 block data format.
Syntax :SENSe<slot>:DATA:SECTion:TRACe:VALUe?
:SENSe:DATA:SECTion:TRACe:VALUe:STRIng
This query returns the most recently received J0 section trace data. The data is returned as an ASCII
string.
Syntax :SENSe<slot>:DATA:SECTion:TRACe:VALUe:STRIng?