Tektronix 071-0855-05 Telescope User Manual


 
Reference: Remote Commands ~ Command Description
3-36 OTS9100 User Manual
:SENSe:MEASure:HDLC:BYTes
This query returns the number of HDLC bytes received with good FCS.
Syntax :SENSe<slot>:MEASure:HDLC:BYTes?
:SENSe:MEASure:IP:PACKets
This query returns the value of the specified result parameter in NR1 format.
Syntax :SENSe<slot>:MEASure:IP:PACKets? <Parameter>
Parameters Description
TOTal Total count of IP bytes received
GOOD Count IP bytes received with good checksum
BAD Count of IP bytes received with bad checksum
FREE Count of IP Packet received with no payload errors
PAYLoad Count of IP Packet received with payload errors
:SENSe:MEASure:IP:PACKets:ALL
This query returns the values of all of the parameters of the SENSe :MEASure:IP:PACKets? query. The
parameters are returned in the order in which they are listed under :SENSe:MEASure:IP:PACKets values
are returned in NR1 format.
Syntax :SENSe<slot>:MEASure:IP:PACKets:ALL?
:SENSe:MEASure:LINE:CUMUlative
This query returns the value of the specified result parameter for the most recent test.
Syntax :SENSe<slot>:MEASure:LINE:CUMUlative? <Enum>
Parameters Description
B2_C B2 errors
B2_ES B2 errored seconds
B2_ER B2 error ratio
REI_C REI errors
REI_ES REI errored seconds
REI_ER REI error ratio
AIS_ES AIS errored seconds
RDI_ES RDI errored seconds
:SENSe:MEASure:LINE:CUMUlative:ALL
This query returns the values of all of the parameters of the :SENSE:MEASURE:LINE:CUMULATIVE?
query. The parameters are returned in the order in which they are listed under
:SENSE:MEASURE:LINE:CUMULATIVE.
Syntax :SENSe<slot>:MEASure:LINE:CUMUlative:ALL?