Tektronix 071-0855-05 Telescope User Manual


 
Reference: Remote Commands ~ Command Description
OTS9100 User Manual 3-19
:SENSe:ANALysis:G826A:RS
This query returns the value of the specified Regenerator Section parameter from G.826 analysis of
received data.
Syntax :SENSe<slot>:ANALysis:G826A:RS? <Enum>
Parameter Description
ETIME Elapsed time
EB_C Errored blocks
EB_R Errored block ratio
BBE_C Background block errors
BBE_R Background block error ratio
ES_C Errored seconds
ES_R Errored second ratio
SES_C Severely errored seconds
SES_R Severely errored second ratio
CSES_C Consecutive SES periods
UAS_C Unavailable seconds
UAS_R Unavailable seconds error ratio
:SENSe:ANALysis:G826A:RS:ALL
This query returns the values of all of the Regenerator Section parameters from G.826 analysis of
received data. The parameters are returned in the order in which they are listed under
:SENSe:ANALysis:G826A:RS.
Syntax :SENSe<slot>:ANALysis:G826A:RS:ALL?
:SENSe:ANALysis:GR253A:LINE:FAR
This query returns the value of the specified Far-End Line parameter from GR-253 analysis of received
data.
Syntax :SENSe<slot>:ANALysis:GR253A:LINE:FAR? <Enum>
Parameters Description
CV_C CV Count
CV_R CV Count Ratio
BBE_C Background block errors
BBE_R Background block error ratio
ES_C Errored seconds
ES_R Errored second ratio
SES_C Severely errored seconds
SES_R Severely errored second ratio
ESA_C Errored seconds type A
ESA_R Errored second type A ratio
ESB_C Errored seconds type B
ESB_R Errored second type B ratio
CSES_C Consecutive SES periods
UAS_C Unavailable seconds
UAS_R Unavailable seconds error ratio