Reference: Remote Commands ~ Command Description
3-58 OTS9100 User Manual
:SOURce:DATA:TOH:STS1A:DEFAult
This command sets all bytes in the generated STS-1 #1 Transport Overhead data to their default values.
Syntax :SOURce<slot>:DATA:TOH:STS1A:DEFAult
:SOURce:INSErt:ANOMaly:MODE
This command specifies how anomalies are inserted. The query form returns the current setting.
Syntax :SOURce<slot>:INSErt:ANOMaly:MODE?
:SOURce<slot>:INSErt:ANOMaly:MODE <Enum>
Parameter Description
NONE Anomaly insertion is disabled
SINGle A single anomaly is inserted
BURSt A burst of anomalies is inserted
:SOURce:INSErt:ANOMaly:RATE
This command sets the rate at which continuously-generated anomalies are inserted. The query form
returns the current value.
Syntax :SOURce<slot>:INSErt:ANOMaly:RATE?
:SOURce<slot>:INSErt:ANOMaly:RATE <NR3>
:SOURce:INSErt:ANOMaly:RATE:RANGe
This query returns the minimum and maximum rate values for the specified anomaly type.
Syntax :SOURce<slot>:INSErt:ANOMaly:RATE:RANGe? <Enum>
Parameters Description
NONE No anomaly is selected
B1BIP B1 parity errors
B2BIP B2 parity errors
B3BIP B3 parity errors
REI Line REI errors
REI_P Path REI errors
PATTern Pattern bit errors
RANDom Errors in randomly-selected framing, overhead, and payload bits
BIT_SPE Errors in randomly-selected SPE bits (SONET mode only)
BIT_VC Errors in randomly-selected VC bits (SDH mode only)