Tektronix 071-0855-05 Telescope User Manual


 
Reference: Remote Commands ~ Command Description
3-20 OTS9100 User Manual
:SENSe:ANALysis:GR253A:LINE:FAR:ALL
This query returns the values of all of the Far-End Line parameters from GR-253 analysis of received
data. The parameters are returned in the order in which they are listed under
:SENSe:ANALysis:GR253A:LINE:FAR.
Syntax :SENSe<slot>:ANALysis:GR253A:LINE:FAR:ALL?
:SENSe:ANALysis:GR253A:LINE:NEAR
This query returns the value of the specified Near-End Line parameter from GR-253 analysis of received
data.
Syntax :SENSe<slot>:ANALysis:GR253A:LINE:NEAR? <Enum>
Parameters Description
CV_C CV Count
CV_R CV Count ratio
BBE_C Background block errors
BBE_R Background block error ratio
ES_C Errored seconds
ES_R Errored second ratio
SES_C Severely errored seconds
SES_R Severely errored second ratio
ESA_C Errored seconds type A
ESA_R Errored second type A ratio
ESB_C Errored seconds type B
ESB_R Errored second type B ratio
CSES_C Consecutive SES periods
UAS_C Unavailable seconds
UAS_R Unavailable seconds error ratio
:SENSe:ANALysis:GR253A:LINE:NEAR:ALL
This query returns the values of all of the Near-End Line parameters from GR-253 analysis of received
data. The parameters are returned in the order in which they are listed under
:SENSe:ANALysis:GR253A:LINE:NEAR.
Syntax : SENSe<slot>:ANALysis:GR253A:LINE:NEAR:ALL?