Tektronix 071-0855-05 Telescope User Manual


 
Reference: Remote Commands ~ Command Description
3-18 OTS9100 User Manual
:SENSe:ANALysis:G826A:PATH:FAR:ALL
This query returns the values of all of the Far-End Path parameters from G.826 analysis of received data.
The parameters are returned in the order in which they are listed under the heading
:SENSe:ANALysis:G826A:PATH:FAR. Ratios are returned as NR3 values, other parameters as NR1
values.
Syntax: :SENSe<slot>:ANALysis:G826A:PATH:FAR:ALL?
:SENSe:ANALysis:G826A:PATH:NEAR
This query returns the value of the specified Near-End Path parameter from G.826 analysis of received
data. Ratios are returned as NR3 values, other parameters as NR1 values.
Syntax: :SENSe<slot>:ANALysis:G826A:PATH:NEAR? <Enum>
Parameters Description
ETIME Elapsed time
EB_C Errored blocks
EB_R Errored block ratio
BBE_C Background block errors
BBE_R Background block error ratio
EFS_C Error-free seconds
EFS_R Error-free seconds ratio
ES_C Errored seconds
ES_R Errored second ratio
SES_C Severely errored seconds
SES_R Severely errored second ratio
CSES_C Consecutive SES periods
UAS_C Unavailable seconds
UAS_R Unavailable seconds error ratio
:SENSe:ANALysis:G826A:PATH:NEAR:ALL
This query returns the values of all of the Near-End Path parameters from G.826 analysis of received
data. The parameters are returned in the order in which they are listed under the heading
:SENSe:ANALysis:G826A:PATH:NEAR. Ratios are returned as NR3 values, other parameters as NR1
values.
Syntax: :SENSe<slot>:ANALysis:G826A:PATH:NEAR:ALL?