Tektronix 071-0855-05 Telescope User Manual


 
Reference: Remote Commands ~ Command Description
3-30 OTS9100 User Manual
:SENSe:DATA:PAYLoad:PATTern:UDATA
This command selects the fixed test pattern for the received signal. The query form returns the current
setting.
Syntax: :SENSe<slot>:DATA:PAYLoad:PATTern:UDATA?
:SENSe<slot>:DATA:PAYLoad:PATTern:UDATA <NR1>
:SENSe:DATA:POH:ALL
This query returns a block of data representing the Path Overhead data from an STS-1 in the received
signal. There are 9 bytes in the block returned. For SONET, these bytes are J1 B3 C2 G1 F2 H4 Z3 Z4
Z5; for SDH, these bytes are J1 B3 C2 G1 F2 H4 F3 K3 N1.
Syntax: :SENSe<slot>:DATA:POH:ALL? [<NR1>]
:SENSe:DATA:POH:BYTE
This query returns a single byte of data from the Path Overhead data for the selected active channel in
the received signal. The numeric parameter, with range 1 to 9, specifies the byte in the order listed under
:SENSe:DATA:POH:ALL.
Syntax: :SENSe<slot>:DATA:POH:BYTE? <NR1>
:SENSe:DATA:POH:BYTE:C2A
This query returns the Path Label (C2) byte from the selected active channel in the received signal.
Syntax: :SENSe<slot>:DATA:POH:BYTE:C2A?
:SENSe:DATA:POS:SCRambling
This command enables or disables the packet over sonnet scrambling. The query form returns the current
setting. <Slot> is an optional number that specifies the module slot containing the device that is the
target of the command; if omitted, it defaults to the lowest-numbered slot containing an applicable device.
Syntax :SENSe<slot>:DATA:POS:SCRambling?
:SENSe<slot>:DATA:POS:SCRambling <Boolean>