Tektronix 071-0855-05 Telescope User Manual


 
Reference: Remote Commands ~ Command Description
OTS9100 User Manual 3-25
:SENSe:ANALysis:PATH:TRACe:EXPEcted:TYPE
This command sets the data sequence length used by the receiver for path Trace Identifier Mismatch
measurements. This parameter may also be set by the :SENSe:ANALysis:PATH:TRACe:EXPEcted
command. The query form returns the current setting of this parameter.
Syntax: :SENSe<slot>:ANALysis:PATH:TRACe:EXPEcted:TYPE?
:SENSe<slot>:ANALysis:PATH:TRACe:EXPEcted:TYPE <Enum>
Parameters Description
L1B Constant 8-bit data
L16B A repeating sequence of 16 bytes, 0-filled with CRC
L16FREE A repeating sequence of 16 bytes, arbitrary format
L64B A repeating sequence of 64 bytes, space-filled with CR/LF
L64FREE A repeating sequence of 64 bytes, arbitrary format
:SENSe:ANALysis:PATH:TRACe:EXPEcted:VALUe
This command sets the data byte values used by the receiver for path Trace Identifier Mismatch
measurements. The data bytes are formatted as a standard IEEE-488 data block. These values may also
be set by the :SENSe:ANALysis:PATH:TRACe:EXPEcted command. The query form returns the current
values.
Syntax: :SENSe<slot>:ANALysis:PATH:TRACe:EXPEcted:VALUe?
:SENSe<slot>:ANALysis:PATH:TRACe:EXPEcted:VALUe <Block>
:SENSe:ANALysis:PATH:TRACe:EXPEcted:VALUe:STRIng
This command sets the data byte values used by the receiver for path Trace Identifier Mismatch
measurements. The byte values are formatted as an ASCII string. These values may also be set by the
:SENSe:ANALysis:PATH:TRACe:EXPEcted command. The query form returns the current values.
Syntax: :SENSe<slot>:ANALysis:PATH:TRACe:EXPEcted:VALUe:STRIng?
:SENSe<slot>:ANALysis:PATH:TRACe:EXPEcted:VALUe:STRIng <String>