Tektronix 071-0855-05 Telescope User Manual


 
Reference: Remote Commands ~ Command Description
OTS9100 User Manual 3-45
:SENSe:TEST:TIME:ELAPsed
This query returns the time since the start of the current test.
Syntax :SENSe<slot>:TEST:TIME:ELAPsed?
:SENSe:TRIGger:MODE
This command sets the condition that will produce a trigger output from the OTS-9000 receiver. The
query form returns the current setting.
Syntax :SENSe<slot>:TRIGger:MODE?
:SENSe<slot>:TRIGger:MODE <Enum>
Parameters Description
OFF The trigger output is disabled
ANOMaly A trigger occurs when an anomaly is received
DEFEct A trigger occurs when a defect is received
PAYload A trigger occurs when a payload data error is received
AD A trigger occurs when an anomaly or defect is received
AP A trigger occurs when an anomaly or payload data error is received
DP A trigger occurs when a defect or payload data error is received
ADP A trigger occurs when an anomaly, defect, or payload data error is received
:SOURce:CLOCk:SOURce
This command selects the timing source for the signal generated by the OTS-9000 transmitter. The query
form returns the current setting.
Syntax :SOURce<slot>:CLOCk:SOURce?
:SOURce<slot>:CLOCk:SOURce <Enum>
Parameters Description
INTErnal Transmitter timing is based on the OTS-9000's internal reference
EXTErnal Transmitter timing is derived from an external signal applied to the clock/trigger card
:SOURce:DATA:BACKground:STRUcture
This command sets the background structure of the signal generated by the OTS-9000 transmitter. The
query form returns the current setting.
Syntax: :SOURce<slot>:DATA:BACKground:STRUcture?
:SOURce<slot>:DATA:BACKground:STRUcture <Enum>
Parameters Description
G10C Bulk data at 10 Gb/s
G2P5C Bulk data at 2.5 Gb/s
M622C Bulk data at 622 Mb/s
M155C Bulk data at 155 Mb/s
M51A Bulk data at 51 Mb/s (SONET only)