Tektronix 071-0855-05 Telescope User Manual


 
Reference: Remote Commands ~ Command Description
3-34 OTS9100 User Manual
:SENSe:MEASure:APSTime:DETEcted
This query returns one or more values to indicate the receiver events detected during the most recently
performed APS measurement.
Syntax: :SENSe<slot>:MEASure:APSTime:DETEcted?
Parameters Description
NONE No conditions were detected
LOS Loss of Signal
OOF Severely Errored Frame / Out of Frame
B1BIP B1 errors
B2BIP B2 errors
B3BIP B3 errors
BIT Bit (payload) errors
AIS_L Line AIS / MS-AIS
AIS_P Path AIS
RDI_L Line RDI / MS-RDI
RDI_P Path RDI
:SENSe:MEASure:APSTime:MAXTime
This command sets the maximum time for APS switch time measurement. The query form returns the
current setting
Syntax: :SENSe<slot>:MEASure:APSTime:MAXTime?
:SENSe<slot>:MEASure:APSTime:MAXTime <NR1>
:SENSe:MEASure:APSTime:RUN
This command starts (1) an APS switch time measurement, or stops (0) any measurement in progress.
Syntax: :SENSe<slot>:MEASure:APSTime:RUN <Boolean>
:SENSe:MEASure:APSTime:STATus
This query returns the status of the most recently performed APS switch time measurement.
Syntax: :SENSe<slot>:MEASure:APSTime:STATus?
Parameters Description
INVALID No valid result is available
BUSY An APS time measurement is in process
PASS The current APS time test passed
FAIL The current APS time test failed