Tektronix 071-0855-05 Telescope User Manual


 
Reference: Remote Commands ~ Command Description
OTS9100 User Manual 3-37
:SENSe:MEASure:LINE:WINDow
This query returns the value of the specified result parameter as measured during the most recent 'N'
seconds. The duration 'N' of the measurement window is set by the :SENSE:MEASURE:WINDOW:SIZE
command.
Syntax :SENSe<slot>:MEASure:LINE:WINDow? <Enum>
Parameters Description
B2_C B2 errors
B2_ES B2 errored seconds
B2_ER B2 error ratio
REI_C REI errors
REI_ES REI errored seconds
REI_ER REI error ratio
AIS_ES Loss-of-signal errored seconds
RDI_ES Loss-of-frame errored seconds
:SENSeMEASure:LINE:WINDow:ALL
This query returns the values of all of the parameters of the :SENSE:MEASURE:LINE:WINDOW? query,
as measured during the most recent N-second period. The parameters are returned in the order in which
they are listed under :SENSE:MEASURE:LINE:WINDOW.
Syntax :SENSe<slot>:MEASure:LINE:WINDow:ALL?
:SENSe:MEASure:PATH:CUMUlative
This query returns the value of the specified result parameter for the most recent test. Ratios are returned
in NR3 format; other values are returned in NR1 format.
Syntax: :SENSe<slot>:MEASure:PATH:CUMUlative? <Enum>
Parameters Description
B3_C B3 errors
B3_ES B3 errored seconds
B3_ER B3 error ratio
REI_C Path REI errors
REI_ES Path REI errored seconds
REI_ER Path REI error ratio
AIS_ES Path AIS errored seconds
RDI_ES Path RDI errored seconds
PLM_ES Path Label Mismatch errored seconds
UNEQ_ES Path Label Unequipped errored seconds
LSS_ES Loss of Synch errored seconds
LOP_ES Loss of Pointer errored seconds
J1TIM_ES Path trace mismatch errored seconds
PAYL_C Payload errors
PAYL_ES Payload errored seconds
PAYL_ER Payload error ratio
RDIPAY_ES Path RDI (Payload) errored seconds
RDICON_ES Path RDI (Connectivity) errored seconds
RDISRV_ES Path RDI (Server) errored seconds