TP-6200 10/12 79Section 2 Operation
Local Programming Mode On
2.8.2 Menu 2—Engine Monitoring
Menu 2 provides engine operating data including oil
pressure and temperature, coolant temperature, fuel
pressure and temperature, engine rpm, and battery
voltage. Menu 2 also displays engine warning and
shutdown setpoints and engine warmed-up and cooled-
down temperature setpoints.
The detailed engine monitoring functions appear only for
DDEC (DDC/MTU), JDEC (John Deere), EMS2 (Volvo),
EDC3 (Volvo), or MDEC/ADEC (DDC/MTU)- equipped
engines.
Note: A right arrow from any submenu moves to the
next submenu header.
Menu 2—Engine Monitoring
Menu 2 Displays with Key Entries
Note: This menu is for monitoring only; no adjustments or user settings can be entered.
Key
Entry Display Description
Input a menu number.
MENU 2
ENGINE MONITORING
Displays the basic engine monitoring heading.
ENGINE MONITORING
BASIC
OIL PRESSURE # PSI
COOLANT TEMP # F
Displays the oil pressure and coolant temperature.
ENGINE RPM #
LOCAL BATT VDC #
Displays the engine cooled down temperature setpoint.
ENGINE COOLED DOWN
#F
Displays the engine rpm and local battery VDC.
Displays the low oil pressure warning and shutdown setpoints.
LOP WARN # PSI
LOP SDOWN # PSI
ENTER MENU NO. 1--15
Press the Enter key.
Displays the menu number and name.
MAIN MENU NUMBER 2
INTAKE AIR # F
OIL TEMP (Waukesha) # F
Displays the intake air and oil temperature
(Waukesha-powered models only)
Displays the high coolant temperature warning and shutdown
setpoints.
HCT WARN # F
HCT SDOWN # F
Displays the engine warmed up temperature setpoint.
ENGINE WARMED UP
#F
Returns the user to basic engine monitoring heading.
ENGINE MONITORING
BASIC
MENU 2
ENGINE MONITORING
Returns the user to the menu number and name.