TP-6200 10/12 113Section 2 Operation
Local Programming Mode On
Menu 10—Output Setup, continued
Menu 10 Displays with Key Entries—
Deactivating the SCRDO
Key
Entry Display Description
Input a menu number.
MENU 10
OUTPUT SETUP
MAIN MENU NUMBER 10
ENTER MENU NO. 1--15
Press the Enter key.
Displays the menu number and name
Displays the common faults heading.
DEFINE COMMON
FAULTS
RELAY DRV OUT XX
S’WARE CONTROLLED #X
Gives the user previously selected items for the relay driver outputs
(RDO). Press the down arrow to scroll through relay driver outputs
1--31 or enter the RDO number. Locate the SCRDO display.
DEACTIVATE RDO?
Press the Enter key.
When required (SCRDO is currently active), enter the YES key to
deactivate the SCRDO.
DEACTIVATE RDO? YES
RELAY DRV OUT XX
S’WARE CONTROLLED #X