Kohler 20-3250 kW Portable Generator User Manual


 
TP-6200 10/1252 Section 2 Operation
2.7 Reviewing Menu Displays
Use this section to review a summary of the generator
set controller data. See Figure 2-17 for which menus
provide data monitoring and adjusting data.
Press the Reset key, enter the desired menu number
key(s), and then press the Enter key. Use the down
arrow and right arrow keys for navigation.
See Section 1, Specifications and Features, to review
set point ranges and default settings for comparison to
the actual setup.
The user must enable the programming mode to edit the
display. See Menu 14—Programming Mode and
Section 2.8, Local Programming Mode On, for more
information.
Note: Press any key on the keypad to activate the
controller panel display. The panel display turns
off 5 minutes after the last keypad entry.
Note: Press the Reset Menu key to clear error
messages.
Note: Press the Menu Right key prior to entering
decimal values where necessary.
Menus displaying the # symbol represent one of the
following data types:
D System-calculated data
D System-measured data
D User-entered data
Menus displaying the ? symbol require the user to enter
data.
Menus displaying the * symbol represent access code or
password type entries. The actual key entry does not
display.
See Section 2.5.3, Request and Error Messages, for
error display messages and explanations while
navigating the menus.
Legend:
Menu Down Key
Menu Right Key
Menu
Number
Menu Name
View Only
Data
View and
Adjust Data
1 Generator Monitoring X
2 Engine Monitoring X
3 Analog Monitoring X
4 Operational Records X
5 Event History X
6 Time and Date X
7 Generator System X
8 Time Delays X
9 Input Setup X
10 Output Setup X
11 Voltage Regulator X
12 Calibration X
13 Communications X
14 Programming Mode X
15 Protective Relays X
20 Factory Setup X
Figure 2-17 Menu Displays for Viewing and Adjusting