Anritsu MG369XB Portable Generator User Manual


 
To access the Sweep Trigger menu (below) from ei
-
ther the Analog Sweep or Step Sweep menus, press
Trigger > .
Select a sweep trigger mode as follows:
q
Press Auto [AUT] to select automatic trigger
-
ing
q
Press External [HWT] to select external trig-
gering
q
Press Single [EXT] to select single sweep trig-
gering
A message showing the sweep trigger mode selected
appears on the right side of frequency title bar.
If you select the single sweep trigger mode, the
menu display adds the menu soft-key Trigger .
Pressing Trigger [TRG or TRS] starts a single
sweep. If a single sweep is in progress, pressing
Trigger [RSS] causes the sweep to abort and reset.
Press < Previous to return to the Additional Step
Sweep menu.
Manual Sweep
Mode
In manual sweep frequency mode, the output fre
-
quency can be manually tuned in phase-locked steps
between the selected start and stop frequencies us
-
ing the cursor control keys or rotary data knob. As
the knob is turned or the Ù or Ú cursor control pads
pressed, the current output frequency is incre
-
mented by the step size and displayed on the data
display as Fm. The step size or number of steps be
-
tween the start and stop frequencies are controlla
-
ble from the manual sweep menu. The step size
range is 0.01 Hz to the full frequency range of the
instrument; the number of steps range is 1 to
10,000.
3-32 MG369XB OM
Sweep Frequency Operation Local (Front Panel) Operation