General Information Options
MG369XB OM 1-5
Model
Number
Configuration
Frequency
Range
MG3691B
With Option 4 or 5
Standard
³0.01 – £10.0 GHz
³2.0 – £10.0 GHz
MG3692B
With Option 4 or 5
Standard
³0.01 – £20.0 GHz
³2.0 – £20.0 GHz
MG3693B
With Option 4 or 5
Standard
³0.01 – £30.0 GHz
³2.0 – £30.0 GHz
MG3694B
With Option 4 or 5
Standard
³0.01 – £40.0 GHz
³2.0 – £40.0 GHz
MG3695B
With Option 4 or 5
Standard
³0.01 – £50.0 GHz
³2.0 – £50.0 GHz
MG3696B
With Option 4 or 5
Standard
³0.01 – £67.0 GHz*
³2.0 – £67.0 GHz*
*Operational to 70.0 GHz
Options List
Option 1A:
Rack Mounting with Slides—Rack mount kit containing a set of track slides (90° tilt capability), mounting
ears, and front panel handles for mounting the instrument in a standard 19-inch equipment rack.
Option 1B:
Rack Mounting without Slides—Modifies rack mounting hardware to install unit in a console that has
mounting shelves. Includes mounting ears and front panel handles.
Option 2X:
110 dB Mechanical Step Attenuator—Adds a 10 dB per step attenuator with a 110 dB range. Output power
is selected directly in dBm on the front panel (or via GPIB). Rated RF output power is reduced.
Option 2E:
120 dB Electronic Step Attenuator—Adds a 10 dB per step attenuator with a 120 dB range for models
having a high-end frequency of £20 GHz. Output power is selected directly in dBm on the front panel (or via
GPIB). Rated RF output power is reduced.
Option 3:
Ultra-Low Phase Noise—Adds new modules that significantly reduces single-sideband phase noise,
³2 GHz.
Option 4:
Digital Down Converter—Adds a digital down converter for ultra-low phase noise for 0.01 to 2.2 GHz RF
coverage.
Option 5:
Analog Down Converter—Adds an analog down converter for 0.01 to 2.0 GHz RF coverage.
Option 6:
Analog Sweep Capability—Adds analog sweep capability. (Limited to ³500 MHz when used with Option 4.)
Option 7:
IF Up-Conversion—Adds an internal 40 GHz mixer for up-converting an IF signal. Not available in
MG3695B, MG3696B, or with Option 18.
Option 8:
Power Monitor—Adds internal power measurement capability. (Not available with Option 9.)
Option 9X:
Rear Panel RF Output—Moves the RF output connector to the rear panel.
Option 10:
User-Defined Modulation Waveform Software—Adds a software package that provides the ability to seri
-
ally (or via GPIB) download user-defined waveforms into the memory of the internal waveform generator.
Requires an external PC and an instrument with an internal low frequency generator (Option 23).
Table 1-1. Series MG369XB Model and Option List (1 of 2)