Anritsu MG369XB Portable Generator User Manual


 
ALC Power
Slope
The ALC power slope function lets you compensate
for system, cable, and waveguide variations due to
changes in frequency. This is accomplished by lin
-
early increasing or decreasing power output as the
frequency increases. As shown in the following illus
-
tration, the power slope function provides you with
the ability to set both the power slope and the pivot
point. The ALC loop menu lets you activate the ALC
power slope function.
To access the ALC Loop menu from the Level ALC
Control menu display, press ALC Loop . The ALC
Loop menu (below) is displayed.
3-68 MG369XB OM
Leveling Operations Local (Front Panel) Operation
Power
Slope
Power at DUT
With Compensation
Power at DUT
Without Compensatio
n
Power Slope
Pivot Point
Frequency
Power Level