Reelmaster 3550- D Page 3 - 11 Kubota Diesel Engine
Removal (Fig. 7)
1. Park machine on a level surface, lower cutting units,
stop engine, engage parking brake and remove key
from the ignition switch.
2. Open and remove hood from the machine.
CAUTION
Do not open radiator cap or drain coolant if the
radiator or engine is hot. Pressurized, hot cool-
ant can escape and cause burns.
Ethylene- glycol antifreeze is poisonous. Dis-
pose of coolant properly or store it in a properly
labeled container away from children and pets.
IMPORTANT: Followall localcodes andregulations
when recycling or disposing engine coolant.
3. Drain radiator into a suitable container either by us-
ing the draincock near the lower left side corner of the
radiator or by removing the lower radiator hose from the
radiator.
4. Disconnect radiator hoses from the radiator.
5. Remove air cleaner inlet hose from radiator opening.
6. Read the General Precautions for Removing and
Installing Hydraulic System Components in the Service
and Repairs section of Chapter 4 - Hydraulic System in
this manual.
7. Thoroughly clean hydraulic lines at oil cooler ports.
Disconnecthydrauliclinesandputcapsor plugsonlines
to prevent contamination. Label disconnected hydraulic
lines for proper installation.
8. Remove coolant expansion tank and bracket from
machine.
9. Remove fan shrouds from machine.
10.Remove fasteners that secure radiator to the upper,
lower and side radiator brackets.
11.Carefully separate radiator/oil cooler assembly from
brackets and remove from the machine.
12.If necessary, remove hydraulic fittingsfrom oil cooler
and discard O- rings.
13.Plug all radiator and hose openings to prevent con-
tamination.
Installation (Fig. 7)
1. Inspect seals around radiator location for wear or
damage. Replace seals if necessary.
2. If hydraulic fittings were removed from oil cooler, lu-
bricate and place new O- rings onto fittings. Install fit-
tings into port openings and tighten fittings (see
Hydraulic Fitting Installation in the General Information
section ofChapter 4 - Hydraulic System inthis manual).
3. If draincock valve was removed from radiator, apply
thread sealant to draincock threads before installing it
into radiator.
4. Remove all plugs placed in radiator and hose open-
ings during the removal procedure.
5. Carefully position radiator to the radiator brackets.
6. Secure radiatorto theside radiatorbrackets withfour
(4) carriage bolts and flange nuts. Secure top and bot-
tom of radiator to brackets with flange head screws.
7. Connect hydraulic lines to fittings in oil cooler ports
(see Hydraulic Hose and Tube Installation in the Gener-
al Information section of Chapter 4 - Hydraulic System
in this manual).
8. Position fan shrouds to radiator and secure with re-
moved fasteners.
9. Secure coolant expansion tank and bracket to ma-
chine.
10.Connect radiator hoses to the radiator and secure
with hose clamps.
11.Install and secure air cleaner inlet hose.
12.Make sure radiator draincock valve is closed. Fill ra-
diator with coolant.
13.Install hood to the machine. Close and latch hood.
14.Fill the hydraulic fluid tank.
15.Start the unit and run engine to normal operating
temperature. Use a ll of the hydraulic controls while the
engine is running to distribute the hydraulic fluid
throughout the s ystem.
16.Stop the engine and check the hydraulic fluid and
coolant levels. Adjust as necessary.
Kubota