Toro 3550-D Lawn Mower User Manual


 
Reelmaster 3550−DPage 5 − 12Electrical System
Output
No.
Output Name Input Conditions Required to Illuminate Output LED
1 START Key Switch − START
Traction Pedal − NEUTRAL
Seat Switch − OCCUPIED or Parking Brake − ENGAGED
Reel Enable/Disable Switch − DISABLE
Joystick − NEUTRAL
2 ETR Key Switch − RUN or START
Traction Pedal − NEUTRAL
Seat Switch − OCCUPIED or Parking Brake − ENGAGED
Engine Coolant Temperature − BELOW 240°F (116°C)
3 GLOW Key Switch − RUN or START
LED illuminates for 6 seconds when key switch is in RUN position.
LED illuminates when key switch is in START position.
4 DIAGNOSTIC
LIGHT
Key Switch − RUN
LED illuminates for 3 seconds when key switch is in RUN position.
5 SV1 (LIFT/
LOWER)
Engine − RUNNING
Mow/Transport Switch − MOW
Reel Enable/Disable Switch − DISABLE
Seat Switch − OCCUPIED
Joystick − LOWER or RAISE
6 (unused) Not used for this product
7 FRONT MOW
(SP)
Engine − RUNNING
Engine Coolant Temperature − BELOW 220°F (105°C)
Mow/Transport Switch − MOW
Reel Enable/Disable Switch − ENABLE
Seat Switch − OCCUPIED
Cutting Units − FULLY LOWERED
8 SV2 (LIFT) Engine − RUNNING
Mow/Transport Switch − MOW
Reel Enable/Disable Switch − DISABLE
Seat Switch − OCCUPIED
Joystick − RAISE
Backlap Switch − MOW
9 SV3 (FRONT EN) Engine − RUNNING
Mow/Transport Switch − MOW
Reel Enable/Disable Switch − DISABLE
Seat Switch − OCCUPIED
Joystick − LOWER or RAISE
10 SV4 (REAR EN) Engine − RUNNING
Mow/Transport Switch − MOW
Reel Enable/Disable Switch − DISABLE
Seat Switch − OCCUPIED
Joystick − LOWER or RAISE
11 ALTERNATOR Key Switch − RUN
12 OVER TEMP Key Switch − RUN
Table 3: Input Conditions Required to Illuminate Diagnostic Display Outputs