Appendix G: Sequence File Text Format
G-2
AWG610 Arbitrary Waveform Generator User Manual
For example,
”SINE.WFM”, ”TRIANGLE.WFM”, ...
”GAUSSN.WFM”, ””, ...
””, ”TRIALGLE.WFM”, ...
When you do not define a file, NULL string (””) must be placed.
Repeat Count. The <F3> is Repeat Count field.
<F3>:=<Repeat Count>|<Infinity>
<Repeat Count>::= 1 to 65536
<Infinity>::= 0
Enhanced Controls. The <F4> to <F6> are Repeat Count, Wait Trigger, Goto
One, and Logic Jump, respectively.
<F4>::=<Wait Trigger>
<Wait Trigger>::= 1 (On) or 0 (Off)
<F5>::=<Goto One>
<Goto One>::= 1 (On) or 0 (Off)
<F6>::=<Logic Jump>
<Logic Jump>::= <Line Number> (range: 1 to 8000)
0 (No definition)
–1 (Jump to next line)
Note that the Logic Jump setting is effective depending on the jump settings
described in next paragraph.
Jump Settings
After the line descriptions, you place the jump setting descriptions as follows:
They can be omitted when you use the current settings.
TABLE_JUMP 0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0
LOGIC_JUMP –1,–1,–1,–1
JUMP_MODE LOGIC
JUMP_TIMING ASYNC
STROBE 0