Tektronix AWG610 Portable Generator User Manual


 
FG Mode
3-226
AWG610 Arbitrary Waveform Generator User Manual
Marker1 and Marker2 signals are generated and output from MARKER OUT1,
MARKER OUT1
, MARKER OUT2 and MARKER OUT2 connectors. The
waveform marker signal has the same form as a pulse waveform. The level and
width of the markers are fixed and cannot be changed. Table 3–55 describes the
marker specification. Marker width depends on the output frequency. Refer to
Table3–56 on page 3–227.
Table 3-55: Predefined Marker signal
Waveform Hi Low Level
Marker1 0 (phase = 0 deg.) to 20 % of
one period of waveform
20 to 100 % of one period of
waveform
Ho : 2.0V
Low : 0.0V
Marker2 0 (phase = 0 deg.) to 50 % of
one period of waveform
Frequency: 65.01MHz to
104.0MHz
0 (phase = 0 deg.) to 52 % of
one period of waveform
50 to 100 % of one period of
waveform
52 to 100 % of one period of
waveform
Hi : 2.0V
Low : 0.0V
Figure 3-76: Marker pattern
Marker signal