The Setup Menu Screen
3-38
AWG610 Arbitrary Waveform Generator User Manual
This button sets the instrument to enhanced output mode. While a waveform is
being output, the Enhanced mode operates the same as the Triggered mode
except for the sequence table output. For sequence table output, the Wait Trigger,
Goto One, and Jump functions specified in the sequence file are enabled.
Pushing the RUN button on the front-panel toggles the output on and off. The
trigger signal is used only to advance a sequence in which Wait Trigger is
stopping on an ON line. When you push the FORCE EVENT button on the
front-panel, the instrument operates in the same way as when the Logic Jump
event signal goes true.
If the enhanced function is set in the sequence, the output will be as follows:
H Wait Trigger. For an ON line, the instrument awaits the trigger before the
waveform is output. The selected trigger source (External or Internal) is
selected.
H Goto One. For an ON line, the control jumps to the head of the sequence
after the waveform is output.
H Logic Jump. When the combination of the event signals connected to the
EVENT IN connector on the rear panel goes true during waveform output of
the line, the control jumps to the specified destination. This also happens
when you push the FORCE EVENT button on the front-panel.
H Table Jump. During waveform output of the line, the control jumps to the
destination specified in the jump table. This depends on the state of the event
signal connected to the EVENT IN connector on the rear panel. For Table
Jump, the FORCE EVENT button will not operate.
H Software Jump. During waveform output of any line, the control jumps to
the destination specified by the argument of a remote command. The
software jump can be performed only with the following command:
AWGControl:EVENt:SOFTware[:IMMediate] <line-number>
H If you specify no destination of jump on the last line of the sequence, control
returns back to the first line after completion of waveform output. (Goto One
automatically goes on.)
Enhanced